MCX-xx
& MCXUNI-BP-xx

 


Contact us


Online documentation

 

ISA bus version

Click to the PDF icon to download the technical data sheet

PCI bus version

mcxpci-BP.JPG (6032 octets)
Click to the PDF icon to download the technical data sheet

8 to 64 synchronous or asynchronous lines under RS232 or RS422
Communication unit SCC 85C30 or 85C230
Software selection of RS232/RS422
External connection case

bp24.jpg (10961 octets)

24 line connection boxes with power supply

Connections:

- External case with connection by an 80 point reinforced round cable
- Up to 8 eight-line cases, that is 64 lines in total.

Signals:

- Software programmable RS interface.
- RS232: TxD, RxD, RTS, CTS, RI, DCD, DTR, TxC, RxC
- RS422: TXa, TXb, RXa, RXb as well as +/- RxC and+/- TxC on lines 1, 2 & 3.

Protocols:

HDLC/SDLC raw mode, HDLC ABM/LAPB, HDLC NRM/SDLC, X25, MONOSYNC, BISYNC, BSC, transparent mode, AHDLC (asynchronous HDLC ISO/IEC 13239), asynchronous synchronised, asynchronous, call us for other protocols.

Peripherals drivers:

Software drivers available for Windows 95/98, Millennium, Windows NT/2000/XP/VISTA, Dos, UNIX SCO, LINUX & RTLinux.

ISA Model:

Available from 8 to 64 lines, with processor 486SX25 or 486SX40 with possibility of addition of an arithmetic co-processor 387.
For further information, please contact us.

PCI Model:

Available from 8 to 64 lines.
For further information, please contact us.

 