COMETH-FIELD-RD

Serial device server RS232/422/485 over Ethernet TCP/IP & MODBUS RTU to MODBUS/TCP data gateway

 


Contact us


Online documentation


Product data sheet


The COMETH-FIELD-RD is a serial device server (RS232/422/485) over Ethernet TCP/IP designed for industrial applications with harsh constraints, particularly in terms of temperature resiliency.
The COMETH-FIELD-RD supports the extended temperature range from -40°C to +80°C.

TELNET support (RFC 2217) and COM port redirector enables the COMETH-FIELD-RD to take advantage of Windows & Linux applications wrote for PC serial devices.

MODBUS/TCP Protocol support allows to connect any RS232 ou RS485 MODBUS equipments to the Ethernet network.

 

 
Instant & direct serial connection over Ethernet TCP/IP network
Ethernet 10/100 auto-detection, plug & play mode auto MDI/MDIX cross-over
RS232 (Sub D9 male), RS422/RS485 (Sub D9 female) serial interface, up to 350 Kb/s sustained data rate
Support for TCP Client/Server, DHCP Client, TELNET RFC2217 extension, Telnet Server, COM port re-director (VIP), multipoint or point to point virtual link over UDP modes and MODBUS/TCP Client/Server, MODBUS/RTU & MODBUS/ASCII protocols
Scanning I/O for all PLC's running MODBUS/RTU & MODBUS/ASCII
Virtual COM port redirection software for Windows 2000, NT & XP (VIP)
Easy administration through the serial link or Ethernet (TELNET)
Multiple configuration tool for volume deployment
Remote firmware download for easy upgrade operations
External power supply from +9VDC to +36VDC
15 kV ESD protection
Metallic case, CE industrial standards
LEDs signalling for serial & Ethernet signals
Extended temperature range from -40°C to +80°C
Ethernet / RS 1500 Veff isolation



Remote COM port mode


Works with Windows 9x/me/NT/2K/XP, Linux and requires a COM port redirector driver software on the PC (VIP).

This mode is supported by the COMETH-FIELD-RD when running the "ServerCom" firmware and when configured in the TELNET RFC 2217 mode (TELNET RFC 2217 is a standard).

This mode makes it possible to run any Windows COM applications without any adaptation (Hyperterminal for example), basically designed for a local COM port, the Windows communication API is fully supported. COM port configuration is carried out by the application itself and not necessarily by the administration module
.

Other redirector softwares relying on the RFC 2217 standard exist for other operating systems.



TCP socket server mode


This mode works with any operating system supporting TCP/IP.
It is supported by the COMETH-FIELD-RD when running the "ServerCom" firmware and when configured in the RAW mode.

The COMETH-FIELD-RD is able to answer to TCP connection request on a configurable TCP port (it is thus a server).

The application which uses the COMETH-FIELD-RD relies on the SOCKET API and not on the COM API.
COM port configuration (speed, characters, flow control) is programmed in the COMETH-FIELD-RD using the administration module.


TCP socket client mode


This mode works with any operating system supporting TCP/IP.
It is supported by the COMETH-FIELD-RD when running the "TCP Client" firmware.

The COMETH-FIELD-RD is able to answer a TCP connection request on a TCP port to a server, the IP address of the server is programmed using the administration module.
Connection origin can be established from COMETH-FIELD-RD power ON of from the rising edge of the DSR signal.

The application which uses the COMETH-FIELD-RD relies on the SOCKET API and not on the COM API.
COM port configuration (speed, characters, flow control) is programmed in the COMETH-FIELD-RD using the administration module.


TELNET mode


This mode works with any operating system supporting TCP/IP and which has a TELNET client software, two cases:

Configured TCP port TCP of the Socket TCP Server mode

This mode is supported by the COMETH-FIELD-RD when running the "ServerCom" firmware and when configured in the TELNET mode.
It doesn't require any application development on the PC, TELNET is the network application !

TCP port #23

This mode is supported by all the COMETH-FIELD-RD's firmwares.
When the COMETH-FIELD-RD receives a port 23 connection request, it switches to the administration mode and can thus be configured (speed, mode ...).


UDP socket mode


This mode works with any operating system supporting TCP/IP.

There's no concept of connection/deconnection and thus no server / client concept in the UDP mode as in TCP. UDP is a transport Protocollike TCP but it works faster and is less advanced.

This mode is supported by the COMETH-FIELD-RD when running the "TUNNEL" firmware and when configured in RAW mode.

The software which uses the COMETH-FIELD-RD relies on the Socket API and not on the COM API.
COM port configuration (speed, characters, flow control) is programmed in the COMETH-FIELD-RD using the administration module.

This mode enables to carry out a point-to-point connection between 2 serial ports while relying on IP but without transport of serial control signals.
Two COMETH-FIELD-RD can be installed on each side but any other equipment supporting UDP can also be connected.


TUNNEL UDP & point-to-point mode


This mode is supported by the COMETH-FIELD-RD when running the "TUNNEL" firmware and when configured in the TUNNELAPP mode.

The software which uses the COMETH-FIELD-RD relies on the Socket API and not on the COM API.
COM port configuration (speed, characters, flow control) is programmed in the COMETH-FIELD-RD using the administration module.

This mode enables to carry out a point-to-point connection between 2 serial ports while relying on IP but with the transport of serial control signals.
Only two COMETH-FIELD-RD can be installed on each side because TUNNELAPP is not a standard Protocol.


MODBUS/TCP data gateway mode


This mode is supported by the COMETH-FIELD-RD when running the "MODBUS/TCP" firmware.

In conformity with the MODBUS/TCP Client / Server specifications, this mode makes it possible to connect any serial MODBUS equipments (MODBUS/ASCII & MODBUS/RTU) to the Ethernet TCP/IP network.

In this mode, the COMETH-FIELD-RD settles like a bridge between the Ethernet network and the serial MODBUS equipments which dramatically simplifies the extension from traditional MODBUS installation to a MODBUS/TCP based installation on the Ethernet network.
The COMETH-FIELD-RD device can work as a slave or master device on both sides (Ethernet or Serial).

This mode also makes it possible to connect between them and in a transparent way several traditional serial MODBUS equipments through the Ethernet network.

COMETH-FIELD-RD with MODBUS/TCP allows moreover integration within the same network of serial MODBUS/ASCII & MODBUS/RTU based equipments and MODBUS/TCP equipments.


Some illustrations


Reference to order:

COMETH-FIELD-RD Serial RS232/RS422/RS485 single channel server over Ethernet TCP/IP, din rail model, +9VDC to +36VDC power supply

 

Accessorie for COMETH-FIELD-RD:

CR9M3FD-2M

RS485 interface cable for COMETH-FIELD-RD, SUB DB9 connector toward 3 wires (TxRx +, TxRx -, GND), lenght 1.70 m, line polarization activated

 

Products | Engineering & Services | Technology | New products | Applications | Distributors | News | On-line services | The company | Home